在建設活動板房之前,活動板房的布局是非常重要的。如果前期布局做的不好,會對使用產生很大的影響,如漏水等。
濟南活動板房廠家為總結了一些活動的布置,董事會會議室的注意事項。
Before the construction of activity board house, the layout of activity board house is very important. If the previous layout is not well done, it will have a great impact on the use, such as water leakage. In order to summarize the arrangement of some activities and the precautions of the board of directors' meeting room, Jinan activity board house manufacturer made a summary.
1.所附墻板布局正確,表面平整;預埋墻板安裝應平整,上下搭接處采用舌槽連接,外板向下搭接,搭接長度不小于15mm。
1. The layout of the attached wallboard is correct and the surface is flat; the installation of the embedded wallboard shall be flat, the upper and lower overlaps shall be connected by tongue and groove, the outer board shall be overlapped downward, and the overlapping length shall not be less than 15mm.
2.移動機房的電路采用PVC管(槽)制作,應用明快,接線整齊美觀;電氣配置符合設計要求;無絕緣老化線,使用壽命長。
2. The circuit of the mobile machine room is made of PVC pipe (slot), which is bright in application, neat and beautiful in wiring; the electrical configuration meets the design requirements; there is no insulation aging line, and the service life is long.
3.防腐:鋼構件應油漆完好,不生銹,外露螺栓應妥善保護;在強腐蝕性環(huán)境下的防腐措施符合設計要求;移動式房屋周圍應排水暢通,無積水,不得堆放雜物。
3. Anti corrosion: the steel members shall be painted in good condition without rust, and the exposed bolts shall be properly protected; the anti-corrosion measures under the strong corrosive environment shall meet the design requirements; the surrounding of the mobile house shall be free of water and sundries.
4.防雷:防雷地面設置符合設計和規(guī)范要求;接地電阻測試合格。
4. Lightning protection: the lightning protection ground shall meet the design and specification requirements; the grounding resistance test shall be qualified.
5.移動式房屋面板安裝應平穩(wěn),檐口平直,板重疊方向正確一致。
5. The panel installation of mobile house shall be stable, the cornice shall be straight, and the overlapping direction of the panel shall be correct and consistent.
6.防火:消防間距應滿足設計和規(guī)范要求,消防通道應暢通;消火栓、滅火器配置符合設計要求,布局合理。廚房火災現(xiàn)場應采取有效的防火保溫措施;金屬夾層板表面含氧量指數(shù)不低于32,木地板等可燃材料應做防火處理。
6. Fire prevention: the fire fighting distance shall meet the design and specification requirements, and the fire fighting channel shall be unblocked; the configuration of fire hydrant and fire extinguisher shall meet the design requirements, and the layout shall be reasonable. Effective fire prevention and insulation measures shall be taken at the site of kitchen fire; the oxygen content index on the surface of metal sandwich panel shall not be less than 32, and fire prevention treatment shall be carried out for combustible materials such as wood floor.
7.活動室圍護板(屋面板和墻板)應無明顯變形、損壞;固定螺栓、防水墊片、金屬墊片、尼龍?zhí)坠艿三R全,連接可靠;密封膠完整有效。
7. The enclosure board (roof panel and wall panel) of the activity room shall be free from obvious deformation and damage; the fixed bolt, waterproof gasket, metal gasket, nylon sleeve, etc. shall be complete and connected reliably; the sealant shall be complete and effective.
以上是濟南活動板房廠家為大家介紹的相關內容,想要了解更多內容,歡迎訪問網站:http://szgdbearing.com
The above is the relevant content introduced by Jinan activity board house manufacturer. If you want to know more, please visit the website: http://szgdbearing.com